SPECIFICATIONS: Vortex Tube
Which Vortex Tube will best suite my needs?
Our Vortex Tube are available in 2 sizes (Small and Medium). Each Vortex Tube is constructed of stainless steel. The wear resistance of stainless steel, as well as its resistance to corrosion and oxidation, assures that STREAMTEK™ Vortex Tube will provide years of reliable, maintenance free-operation.
7500 Series Vortex Tube Specifications
The 7500 series Vortex Tube are used in most industrial applications, such as electrical control panel cooling, tool cooling, and parts cooling. These Vortex Tubes optimize airflow and temperature drop to produce maximum cooling power or Btu/hr. (Kcal/hr.).
Size |
Model No. |
Air Consumption |
BTU/Hr. @ 100 PSIG |
Kcal / Hr. @ 6.9 |
| Small | 7502 | 2 SCFM (57 SLPM) | 145 BTU/Hr. | 37 |
| Small | 7504 | 4 SCFM (113 SLPM) | 275 BTU/Hr. | 69 |
| Small | 7508 | 8 SCFM (227 SLPM) | 560 BTU/Hr. | 141 |
| Medium | 7510 | 10 SCFM (283 SLPM) | 700 BTU/Hr. | 176 |
| Medium | 7515 | 15 SCFM (425 SLPM) | 1100 BTU/Hr. | 277 |
| Medium | 7525 | 25 SCFM (708 SLPM) | 1800 BTU/Hr. | 454 |
| Medium | 7530 | 30 SCFM (850 SLPM) | 2060 BTU/Hr. | 519 |
| Medium | 7540 | 40 SCFM (1133 SLPM) | 2800 BTU/Hr. | 706 |
7700 Series Vortex Tube Specifications
The 7700 series Vortex Tube are used in applications which require extreme cold termperatures such as circuit board testing, and lab sampling cooling. These Vortex Tubes provide the lowest cold air temperatures, but at a low cold airflow (when less than a 50% cold fraction is used). The 7700 services Vortex Tubes should be only used when temperatures below 0º (-18ºC).
Size |
Model No. |
Air Consumption |
BTU/Hr. @ 100 PSIG |
Kcal/Hr. @ 6.9 BAR |
| Small | 7702 | 2 SCFM (57 SLPM) | -- | -- |
| Small | 7704 | 4 SCFM (113 SLPM) | -- | -- |
| Small | 7708 | 8 SCFM (227 SLPM) | -- | -- |
| Medium | 7710 | 10 SCFM (283 SLPM) | - | -- |
| Medium | 7715 | 15 SCFM (425 SLPM) | -- | -- |
| Medium | 7725 | 25 SCFM (708 SLPM) | -- | -- |
| Medium | 7730 | 30 SCFM (850 SLPM) | -- | -- |
| Medium | 7740 | 40 SCFM (1133 SLPM) | -- | -- |
Other Factors
Inlet Air Temperature
The STREAMTEK™ Vortex Tube will provide a temperature drop from the temperature of the compressed air supply.
Back Pressure
A low back pressure, up to 2 PSIG (.1 BAR), will not affect the performance of the STREAMTEK™ Vortex Tube. Anything over this will have a performance degration of ~ 5ºF (2.8ºC).
Filtration
Filtration to maintain clean air is necessary at a rate of 25 microns or less. STREAMTEK™ filters contain a 5 micron element and are properly sized for airflow.
Noise/Muffling
Both Small and Medium Vortex Tubes can be quite noisey if unducted. STREAMTEK™ offers mufflters for both cold and hot air discharge. If the cold air is ducted, muffling is not usually required.
Vortex Tube Specifications
PSIG |
Cold Fraction |
||||||||
| 10% | 20% | 30% | 40% | 50% | 60% | 70% | 80% | 90% | |
20 |
63F | 35C |
62F | 34C |
60F | 33C |
56F | 31C |
51F | 28C |
44F | 24C |
36F | 20C |
28F | 15C |
17F | 9C
|
7F | 4C
|
15F | 8C
|
25F | 14C
|
36F | 20C
|
50F | 28C
|
64F | 36C
|
83F | 46C
|
107F | 59C |
148F | 82C
|
|
40 |
91F | 51C |
88F | 49C |
85F | 47C |
80F | 44C |
73F | 41C |
63F | 35C |
52F | 28C |
38F | 21C |
26F | 14C |
9F | 5C |
21F | 11C |
35F | 19C |
52F | 29C |
71F | 39C |
92F | 51C |
117F | 65C |
147F | 82C |
220F | 122C |
|
60 |
107F | 59C |
104F | 58C |
100F | 56C |
93F | 52C |
84F | 47C |
73F | 41C |
60F | 33C |
45F | 25C |
29F | 16C |
10F | 6C |
24F | 13C |
40F | 22C |
59F | 33C |
80F | 44C |
104F | 58C |
132F | 73C |
168F | 93C |
236F | 131C |
|
80 |
119F | 66C |
115F | 64C |
110F | 61C |
102F | 57C |
92F | 51C |
80F | 44C |
66F | 36C |
49F | 27C |
31F | 17C |
11F | 7C |
25F | 14C |
43F | 24C |
63F | 35C |
86F | 48C |
113F | 63C |
143F | 79C |
181F | 101C |
249F | 138C |
|
100 |
127F | 71C |
123F | 68C |
118F | 66C |
110F | 61C |
99F | 55C |
86F | 48C |
71F | 39C |
53F | 29C |
33F | 18C |
12F | 8C |
26F | 14C |
45F | 25C |
67F | 37C |
91F | 51C |
119F | 66C |
151F | 84C |
192F | 107C |
252F | 140C |
|
120 |
133F | 74C | 129F | 72C | 124F | 69C | 116F | 64C | 104F | 58C | 91F | 50C | 74F | 41C | 55F | 31C | 34F | 19C |
| 13F | 8C | 27F | 14C | 46F | 26C | 69F | 38C | 94F | 52C | 123F | 68C | 156F | 87C | 195F | 108C | 257F | 142C | |
| The percentage of cold air produced versus total filtered compressed air consumed by vortex tube. | ||
| Pounds per Square Inch Gauge | ||
| Drop in temperature. | ||
| Rise in temperature. |
Actual Vortex Tube Performance
The cold fraction is the "percentage flow" of the airflow at cold end. So a 60% cold fraction means 60% of airflow comes out cold end and 40% goes out the hot end.
The above table is for the 7500 Series (10-15 SCFM) Medium sized vortex tubes. The performance can significantly change for higher flow designs. With that said, it's not generally important to get such "low" tempueratures and in most application the Vortex Tube is "preset" to produce a specific temperature drop.
The cold fraction table above is ONLY for the STREAMTEK 7500 Series Generators, or as some competitors like to call ('H' Generators). The 7700 Series Vortex Tube ('C' Generators), produce very cold temperatures but with a lower cold end flow. The 7700 Generators are not designed for high BTU/Hr (or watt) cooling effect.
Temperature drop and Cold end airflow vary inversely between the two as the "cold fraction" changes. The cooling effect is a balance and combination of both outlet flow and temperature drop. Colder temperatures produces do NOT always mean the absolute highest cooling effect will be produced.